RDM Responder Testing
From OpenDMX.net
(Redirected from OLA RDM Responder Testing)
As part of the Open Lighting Project a suite of tests for RDM responders has been developed. This enables manufacturers to check how well a RDM device conforms to the E1.20 specification. The tests cases are written in Python, and use the Open Lighting Architecture to communicate with devices.
Useful Links:
[edit] Test Categories
Tests are grouped according to the sections in the RDM Categories/Parameter ID Defines table in the E1.20 document. There are some extra categories for specific behavior like error conditions and sub device handling.
[edit] Test Coverage
As of 27th March 2011 the following PIDs in E1.20 aren't tested:
- DISC_UNIQUE_BRANCH
- DISC_MUTE
- DISC_UN_MUTE
- STATUS_MESSAGES
- STATUS_ID_DESCRIPTION
- SUB_DEVICE_STATUS_REPORT_THRESHOLD
- RESET_DEVICE
[edit] Test States
There are four possible result states for a test:
- Passed
- The responder replied with the expected result
- Failed
- The responder failed to reply, or replied with an un-expected result
- Not Run
- This test wasn't run because the responder doesn't support the required functionality or a previous test failed.
- Broken
- An internal error occurred, this indicates a programming error or an error with the test rig.
[edit] Log Messages
- Warnings
- Warnings indicate behavior that doesn't match the standard, but is unlikely to cause usability issues. Warnings are printed in the summary section of the test output.
- Advisory Messages
- Advisory messages indicate issues that are not covered by the standard but are likely to cause problems i.e a sensor temperature out side of the stated scale range.